200 MW Energy Storage Fire Protection Project in Dongying

Fiber communication links support reliable fire detection across energy storage containers.

Project Value

Enhancing Fire Protection Communication Reliability

Enhancing Fire Protection Communication Reliability

Fiber-optic ring networks provide reliable transmission of fire protection data while reducing interference and signal attenuation associated with long-distance electrical signal transmission.

Adapting to High-Voltage Energy Storage Environments

Adapting to High-Voltage Energy Storage Environments

With inherent electrical isolation, fiber-optic communications are well suited to high-voltage, high-interference energy storage environments.

Enabling Centralized Connectivity Across Multiple Containers

Enabling Centralized Connectivity Across Multiple Containers

The container-level and station-level ring network architecture enables centralized aggregation of fire protection data from multiple battery containers.

Supporting Energy Storage Safety Management

Supporting Energy Storage Safety Management

The solution provides a stable industrial communication network for data acquisition and coordinated operation within the energy storage fire protection system.

Case Highlights

Case Highlights

Project Background

The Dongying Independent Shared Energy Storage Project of Shandong Energy Group has a planned capacity of 200 MW / 400 MWh. The project adopts a high-voltage cascaded architecture and prefabricated containerized design, incorporating lithium iron phosphate batteries, power conversion systems (PCS), and an Energy Management System (EMS), together with a dedicated energy storage fire protection system.

With a large number of battery containers distributed across a wide area, the fire protection system places high demands on the stability and anti-interference performance of communication links.

Project Requirements

Strong Electromagnetic Interference: Battery clusters operate in a high-voltage DC environment, where conventional electrical signal transmission can be susceptible to ground loops and electromagnetic interference.

Long Distances Between Containers: The large distances between battery containers can cause signal attenuation when conventional CAN bus communication is used over long distances.

Ground Potential Differences: Potential differences may exist between different prefabricated containers. Abnormal conditions such as lightning strikes and surges can affect conventional cable-based signal transmission.

High Reliability Requirements for Fire Protection Communications: Fire detection data must be transmitted reliably to the fire protection sub-control units and the station-level fire protection master control system.

Solution

The project adopted an industrial-grade fiber-optic communication solution to build the communication network for the energy storage fire protection system.

At the container level, 20 ICP222 switches were deployed to form ring networks, enabling stable transmission of data collected by battery status detectors to the fire protection sub-control units. At the station level, 36 ICP222 switches were deployed to connect the fire protection sub-control units of 36 battery containers in a ring network and centrally transmit the data to the fire protection master control system of the centralized control system.

By replacing long-distance conventional electrical signal transmission with fiber-optic ring networks, the solution reduces the impact of complex electrical environments on fire protection communication links.